Compact Muti-Channel AC/DC Power Analyzer

Product Model::
AN87400G(F)

Application:
PV inverter test, Electrical vehicle power supply performance test,

Compact Muti-Channel AC/DC Power Analyzer

Product overview

Download Latest Product Catalog

Wiring Method Channel 1 Channel 2 Channel 3 Channel 4
Single-Phase Photovoltaic Inverter 1P2W 1P2W 1P2W 1P2W
DC AC
Three-phase Photovoltaic Inverter 3P3W/3V3A/3P4W 1P2W
AC DC
Electric Vehicles 1P2W 1P2W 1P2W 1P2W

Product features

· Basic Accuracy: 0.05% * reading + 0.05% range

· Measurement Bandwidth: DC, 0.5Hz – 100kHz

· Sampling Rate: 200kSps

· Maximum Voltage: Standard 1,000V, optional 1,500VDC

· Maximum Current: 20A(standard)/5A/1A. Supports mixed combinations, optional sensor configuration

· LCD Display: Touch screen experience, customizable display interface items, and waveform display

· Date Storage: customizable storage projects, CSV format export

· Perfect Size: 3U half-width size, meeting system integration requirements

Product application

Photovoltaic Inverter Power Measurement

· Complying with Testing Specification for Photovoltaic Grid-connected Inverter(GB/T37409-2019).

· Voltage range: 0 – 1,500V.

· Current range: 0 – 20A/current sensor.

· Capable of simultaneous measuring input, output (single-phase and three-phase) power and power factor.

· Automatic efficiency calculation.

· Analysis of 100 times harmonics and distortion.

· Bidirectional power measurement.

PV Inverter Test Application of Compact Multi-channel Power Analyzer

Electric Vehicle Electrical Performance Measurement

· Multi-channel, capable of simultaneously detecting multiple parameters: OBC efficiency testing, charging station efficiency  testing, battery charging and discharging performance, power conversion performance, motor performance, etc.

· AC/DC, with maximum current 20A, expandable to larger current sensors.

· High precision, with basic precision 0.05% and minimum power resolution 0.1mW.

· Capable of measuring instantaneous effective value, average value, peak value of AC/DC signals, energy consumption, etc.

Electric vehicle electrical performance mesurement

Technical specifications

Model AN87400G(F)
Measurement Channels-x 1 – 4
Wiring Method 1P2W(single-phase 2-wire), 1P3W(single-phase 3-wire), 3P3W(three-phase 3-wire,2 voltage 2 current).

3P3W(3V3A)(three-phase 3-wire, 3 voltage 3 current), 3P4W(three-phase 4-wire)

Measurement Parameters Voltage (U), Current (I)

Active Power (P), Reactive Power (Q), Apparent Power (S), Power Factor (A),

Voltage Frequency(fU), Current Frequency (f)

Phase Angle (Φ), Efficiency (η)

Total Energy (Wh), Forward Energy (Wh+), Reverse Energy (Wh-), Current Integration (Ah)

100 times harmonic distortion factor(HDF)

Total harmonc distortion (THD) of voltage and current

Peak voltage (Vpk), Peak current (lpk)

Voltage peak factor (CfU), Current peak factor (Cfl)…

Input Impedance Voltage: approximately 2MΩ

Current direct input: approximately 10mΩ

Current sensor input: approximately 100kΩ

AD Sampling Rate Approximate 200kS/s
Full range peak factor 3 or 6
Voltage rated ranges (direct

input)

When the peak factor is 3: 15/30/60/100/150/300/600/1000*[V]

When the peak factor is 6: 7.5/15/30/50/75/150/300/500*[V]

* Full range peak factor is 1.5

Current rated ranges(direct Input) When the peak factor is 3:

20A current specifications:500m/1/2/5/10/20*[A]

5A current specifications:100m/200m/500m/1/2/5*[A]

1A current specifications:20m/50m/100m/200m/500m/1*[A]

When the peak factor is 6:

20A current specifications:250m/0.5/1/2.5/5/10*[A]

5A current specifications:50m/100m/250m/0.5/1/2.5*[A]

1A current specifications:10m/25m/50m/100m/250m/0.5*[A]

* Fullrange peak factor of above specifications is 1.5

Current rated ranges

(BNC sensor)

When the peak factor is 3:200m/500m/1/2/5/10[V]

When the peak factor is 6:100m/250m/0.5/1/2.5/5[V]

Voltage and current range (1%-110%)*×range
Accuracy range The accuracy range for voltage of 1,000V and current of 20A is(1%-100%)×range.
Power factor range ±(0.001-1.000)
Voltage measurement accuracy DC ±(0.05%×display value+0.1%×range)
0.1Hz<f<45Hz ±(0.1%×display value+0.1%×range)
45Hz<f≤66Hz ±(0.05%×display value+0.05%×range)
66Hz<f≤1kHz ±(0.1%×display value+0.1%×range)
1kHz<f≤10kHz ±({0.1+0.05×(f-1)}%×display  value+0.2%×range)
10kHz<f≤100kHz ±({0.5+0.04×(f-10)}%×display value+0.3%×range)
Current measurement accuracy DC ±(0.05%×display value+0.1%×range)
0.1Hz<f<45Hz ±(0.1%×display value+0.1%×range)
45Hz<f≤66Hz ±(0.05%×display value+0.05%×range)
66Hz<f≤1kHz ±(0.1%×display value+0.1%×range)
1kHz<f≤10kHz ±(0.1×f)%×display value+0.2%×range)
10kHz<f≤100kHz ±({1+0.08×(f-10)}%×display  value+0.3%×range)
Power measurement accuracy DC ±(0.05%×display value+0.1%×range
0.1Hz<f<45Hz ±(0.1%×display value+0.1%×range)
45Hz<f≤66Hz ±(0.05%×display value+0.05%×range)
66Hz<f≤1kHz ±(0.2%×display value+0.1%×range)
1kHz<f≤10kHz ±({0.2+0.1×(f-1)}%×display value+0.2%×range)
10kHz<f≤50kHz ±({0.2+0.1×(f-1)}%×display value+0.3%×range
50kHz<f≤100kHz ±({5.1+0.18×(f-50)}%×display value+0.3%×range)